Post-tension concrete slab repair on a South Florida structure

Post-Tension Cable Repair in Miami & South Florida

From broken steel cables to corroded anchors — we restore post-tensioned structures across Miami-Dade, Broward, and Palm Beach County with tendon replacement, post-tension slab repair, barrier cable work, and grout injection, performed by crews trained on stored-energy systems.

State-Licensed GC — CGC#1531273
OSHA-Certified Team
Fully Insured & Bonded
4.950+ Google Reviews
500+ Structures Restored
25+ Years of Combined Experience
3 Counties Served
CGC#1531273 — State Certified
The Problem

When a Post-Tension Tendon Fails, the Structure Loses Strength

Post-tensioning is a form of prestressed concrete: high-strength steel cables, called tendons, run through the slab inside protective sheaths and are tensioned to hold the concrete in compression. Those cables are what let South Florida's high-rises, condominiums, and parking structures carry heavy loads on thin, long-span slabs.

That strength has a weak point. In Miami's salt air, chlorides and moisture find their way to the steel — through cracks, failed anchor pockets, and voids in grouted ducts. The strand corrodes, loses cross-section, and can break, usually at the slab edge. Because a tendon is under enormous tension, cable failure is sudden, and the lost capacity transfers to the concrete around it.

New Age Construction Group restores post-tensioning systems safely — locating and assessing tendons, replacing what has failed, rebuilding anchorages, and protecting the steel — for condominiums, HOAs, commercial buildings, and parking garages across Miami-Dade, Broward, and Palm Beach County.

View Our Post-Tension Projects
Post-tension anchor and slab-edge repair on a building
25+ Years
Structural Restoration Experience
Rust staining and cracking at a post-tensioned slab edge
Free
Post-Tension Assessments
Warning Signs

7 Signs Your Post-Tension System Needs Attention

Post-tension problems hide inside the slab until they surface at the edges. These are the signs our crews look for across South Florida — and with post-tensioned structures, early is everything.

Rust stains at slab edges or anchors — reddish-brown bleed at the edge of a slab or balcony often means an anchor is corroding inside.

Cracking along a cable line — cracks that run in a straight line across a slab can follow a tendon that is corroding and expanding.

Blowouts at the slab edge — concrete that has burst or spalled at the edge of a slab or balcony can indicate a failed or failing anchor.

Spalling on balconies or parking decks — surface spalling on post-tensioned elements exposes and accelerates tendon corrosion inside.

Water staining under the slab — leaks and water infiltration reaching a post-tension slab feed the corrosion that attacks the steel cables.

Cracks concentrated around anchor pockets — distress at the slab edge where the anchorages sit is a classic early sign of trouble.

Post-tension-era construction — many South Florida slabs and decks built from the 1970s on are post-tensioned and due for assessment, even without obvious symptoms.

Seeing any of these? Schedule a free assessment
Our Capabilities

Complete Post-Tension Cable Repair Services

From ground penetrating radar (GPR) mapping to tendon replacement and anchor protection — specialized post-tension repair services, done safely and to the engineer's design.

Cable Inspection & Diagnostics

We locate and assess post-tension tendons — mapping cable layouts with ground penetrating radar, finding corrosion and breaks, and diagnosing the cause before any repair begins.

Broken & Corroded Tendon Replacement

Safe de-tensioning, extraction, and replacement of failed tendons — bonded and unbonded systems alike — restoring the slab's designed strength.

Post-Tension Slab & Beam Repair

Structural post-tension slab repair and beam repair: unsound concrete removed, reinforcement treated, and the section rebuilt to the engineer's design.

Anchor Head & Pocket Restoration

Repair and reconstruction of corroded anchor heads, anchorages, and pockets at the slab edge — where post-tensioning systems most often fail.

Grout Injection & Duct Sealing

Filling voids in grouted tendon ducts, repairing damaged sheathing, and sealing anchors, so moisture and chloride can't restart the corrosion.

Barrier Cable Repair & Replacement

Inspection, re-tensioning, and full replacement of corroded barrier cable systems at parking garage edges — the cables that protect people and vehicles at every open bay.

Engineering Coordination & Documentation

Full coordination with your engineer of record, and a record of every tendon repaired — essential for post-tensioned work and inspection sign-off.

What Is Post-Tension Cable Repair?

Post-tension cable repair restores the tensioned steel cables that give a post-tensioned concrete structure its strength. Patching the surface does nothing for the cable inside — repair means re-establishing tension safely: replacing or splicing the strand, restoring the anchorage, and returning the slab to its engineered design.

How Post-Tension Systems Fail

Failures almost always start with water. Chlorides and moisture reach the steel through a cracked slab, a failed anchor pocket, a damaged sheath, or voids in a grouted duct. Tendon corrosion eats the strand's cross-section until it breaks — often at or near the anchorage, and often without warning. South Florida's coastal exposure makes this the dominant threat to the service life of post-tensioned concrete structures here.

Our Repair Process

Every repair starts with diagnostics: GPR mapping, visual assessment, and openings at the anchor pockets where the engineer directs. Where replacement is required, we de-tension the cable safely, extract or expose the damaged strand, splice or replace it, re-stress it to the engineer of record's specification, and verify elongation. Then comes corrosion protection — regrouting ducts, restoring encapsulation, sealing anchor pockets — before we rebuild the surrounding concrete. Materials are specified for salt exposure, so the repair outlasts the conditions that caused the failure.

Safety & Engineering Discipline

A stressed tendon stores enormous energy. Cutting or releasing one incorrectly is genuinely dangerous, which is why post-tension repair is specialist work, not general concrete repair. Our crews are trained on stored-energy hazards, follow engineered de-tensioning procedures aligned with Post-Tensioning Institute (PTI) and ACI practice, and document every step — so the repair process is as defensible as it is safe.

Repair, Splice, or Replace? How the Decision Gets Made

Not every damaged cable needs full replacement — and not every cable is worth saving. The engineer of record weighs its condition, location, and role in the structure:

Re-stress or splice. If the strand is sound but an anchor failed — or a cable was nicked during coring — it can often be spliced with couplers and re-stressed to specification. Fast, contained, least invasive.

Full tendon replacement. Severe tendon corrosion or a broken strand usually means extracting the cable and installing a new one through the existing duct — restoring full design capacity.

Selective abandonment or supplemental strengthening. Occasionally the engineering favors leaving a non-critical cable and strengthening externally instead of an invasive extraction. We price and build whichever option the engineer supports.

That's why diagnostics come first: a splice and a slab-wide replacement program are very different scopes — your proposal should reflect the real one.

Don't Wait

A Failing Tendon Is a Serious Structural Risk

Post-tension problems are hidden and high-stakes. Here's what's at stake when post-tension distress goes unaddressed.

Sudden Failure

A corroded cable under tension can let go without warning, transferring load to the surrounding structure. Post-tension cable failure is among the most serious structural risks a building can carry.

It Hides Until It's Serious

Corrosion happens inside the slab — invisible until rust staining, cracking, or an anchor blowout appears. By then the tendon is already compromised, and the structural integrity of that bay is in question.

Scope Grows With Time

One failing tendon rarely stays one. Early assessment contains the repair before damage spreads to adjacent cables and concrete.

Pricing Transparency

What Determines Post-Tension Repair Costs in South Florida

No two post-tension failures are the same. These four factors drive the price of every post-tension repair we estimate.

Number & Condition of Tendons

Restoring one anchor is a different scope than replacing corroded cables across a slab. Diagnostics establish how many tendons are affected, and how badly.

Repair Type & Access

Anchor restoration, splicing, and full replacement carry different labor and engineering profiles — and high-rise or elevated-deck access adds to it.

Concrete Scope

Post-tension work usually means concrete removal and reinstatement around the cable; the amount of structural concrete repair drives cost.

Engineering & Documentation

Engineered procedures, coordination, and tendon-by-tendon records — we manage and itemize all of it.

Every New Age proposal is free, itemized, and tied to a documented scope. No allowances that balloon later, no hidden mobilization fees.

Get your itemized assessment

A failing tendon won't wait. Get your post-tension system assessed before it lets go.

Book a free, no-obligation post-tension assessment this week.

How It Works

From First Call to Final Sign-Off

A clear, structured process with no surprises at any stage.

01

Free Assessment

We visit your property at no cost to locate and assess the post-tension tendons and document every area of concern.

02

Scope & Itemized Proposal

A transparent proposal with full scope, engineered procedures, timeline, and pricing — no hidden fees.

03

Specialist Execution

Trained crews de-tension, repair, and re-stress tendons to the engineer's specifications.

04

Final Inspection & Documentation Hand-Off

A quality walkthrough plus the tendon-by-tendon repair record your engineer and board keep on file.

Why New Age

The Post-Tension Repair Team South Florida Trusts

OSHA-Certified Workforce

Every superintendent holds a 30-hour OSHA certification; every laborer completes 10-hour OSHA training. Safety is an operating standard, not a checkbox.

State-Licensed & Fully Insured

Certified General Contractor CGC#1531273, with General Liability and Workers' Compensation on every project.

25+ Years of Structural Restoration Experience

Our leadership team has spent decades restoring concrete structures in Miami's coastal environment — corrosion is the problem we know best.

On-Time, On-Budget Delivery

Meticulous planning and proactive communication, so projects finish on schedule and within the agreed budget.

Florida Compliance

Post-Tension Repair and Your Milestone Inspection or 40-Year Recertification

If your building is three stories or taller, Florida's milestone inspection law (SB 4-D) requires a structural inspection at 30 years — 25 near the coast — and every 10 years after. In Miami-Dade and Broward, the 40-year recertification runs alongside it. Post-tensioned parking decks, balconies, and elevated slabs are exactly where these inspections find trouble: rust at anchors, spalling, cracking along cable lines.

When an engineer's report flags post-tension distress, the repair has to be performed — and documented — before the finding can be closed out. That's the work we do every week: engineered tendon repairs with the records your board, your engineer, and the building department need. And because tendon damage rarely travels alone, we coordinate the surrounding concrete restoration, structural repair, and waterproofing under one contractor, one schedule, one point of accountability.

Inspection report in hand? Send it over — we'll price the repairs line by line.

Send Us Your Inspection Report
3+Stories — condominium buildings covered by Florida's SB 4-D milestone inspection law
25–30Years — building age when the first milestone inspection is due (earlier near the coast)
10Years — reinspection cycle after the first milestone inspection
Our Work

Post-Tension Projects We're Proud Of

Brickell Tower Post-Tension Slab Repair
Post-Tensioning Repair

Brickell Tower Post-Tension Slab Repair

Miami-Dade County
View Project
Fort Lauderdale Parking Deck Tendon Restoration
Post-Tensioning Repair

Fort Lauderdale Parking Deck Tendon Restoration

Broward County
View Project
Boca Raton Elevated Slab Post-Tension Repair
Post-Tensioning Repair

Boca Raton Elevated Slab Post-Tension Repair

Palm Beach County
View Project
Engineering Standards

Post-Tension Repair Done Safely, to Engineering Standards

Post-tension repair is specialized structural work — a tendon stores enormous energy, and it has to be assessed, de-tensioned, and restored to engineered procedures by crews trained on post-tension systems. It is not general concrete repair, and the difference is a matter of safety and structural integrity. New Age performs post-tension repair to recognized post-tension and concrete-repair standards, coordinated with your engineer of record.

We document every tendon assessed and repaired, so your engineer, your board, and any milestone inspection have a verifiable record. On post-tensioned structures, that documentation is as important as the repair itself.

Ask About Post-Tension Repair
TrainedCrews trained on the stored-energy hazards of post-tension systems
PTI/ACIPost-tension and concrete-repair practices our work follows
100%Documented — every tendon assessed and repaired, recorded for sign-off
Client Testimonials

What Property Owners & Managers Are Saying

Google Reviews4.9

"Their post-tensioning repair work on our parking structure was flawless. Knowledgeable, courteous, and completed the project on time and within budget."

JT
Jennifer T.
Verified Google Review

"New Age Construction completely restored the structural damage on our building. Professional team, excellent communication, and the results exceeded our expectations. Highly recommend."

MR
Maria R.
Verified Google Review

"Outstanding service from start to finish. The team was professional, efficient, and delivered exceptional results on our commercial project."

RM
Robert M.
Verified Google Review
4.9
Based on 50+ Google Reviews
Coverage Area

Post-Tension Cable Repair Across South Florida

We assess and repair post-tensioning systems for condominiums, HOAs, commercial owners, and parking structures throughout Miami-Dade, Broward, and Palm Beach County.

Miami-Dade County

From Brickell and Aventura high-rises to Sunny Isles parking garages, we handle parking garage repair and post-tension work across Miami, Hialeah, Doral, and Homestead, with deep familiarity with Miami-Dade's building department.

Broward County

Our crews restore post-tensioned parking decks and elevated slabs in Fort Lauderdale, Hollywood, Pembroke Pines, Miramar, and Sunrise — built for Broward's coastal exposure.

Palm Beach County

From West Palm Beach to Boca Raton, Delray Beach, and Boynton Beach, we repair post-tension systems for condominium associations and commercial owners — including tendon work tied to milestone inspections.

Seeing Cracks or Rust Along a Slab Edge?

Post-tension problems don't get better on their own. Schedule a free assessment with our trained team today.

Call (786) 786-1006
FAQ

Frequently Asked Questions About Post-Tension Cable Repair

Get Started

Request Your Free Post-Tension Assessment

A senior project manager will contact you within 24 hours to schedule a no-obligation site visit — an honest read on your system's condition, its durability, and what it will take to restore it.

Free site visit — no obligation
Response within 24 hours
Licensed GC on every assessment
Prefer to call?
(786) 786-1006

Tell Us About Your Post-Tension Project

By submitting this form you agree to be contacted by our team. We never share your information.