Get a Free Assessment
Temporary shoring posts stabilizing a concrete structure

Emergency Shoring & Structural Stabilization in Miami and South Florida

Rapid response temporary supports for distressed, storm damaged and unsafe buildings. Engineer coordinated, permitted and carried through to the permanent structural repair across Miami-Dade, Broward and Palm Beach County.

State Licensed GC CGC#1531273
OSHA Certified Crews
Fully Insured & Bonded
★★★★★
4.950+ Google Reviews
500+ Structures Restored
25+ Years of Combined Experience
3 Counties Served
CGC#1531273 — State Certified
The Problem

When a Structure Shows Distress, the First Job Is Making Sure It Doesn't Fail

Emergency shoring is the rapid installation of engineered temporary supports that carry the load a damaged column, beam, slab or load-bearing wall can no longer be trusted to carry. It does not fix the element. It takes the weight off it so the building stays safe while the cause is diagnosed and the permanent repair is designed, permitted and built.

A column crushing at its base. Concrete dropping from a parking garage ceiling. A balcony slab sagging after a hurricane. The permanent fix takes structural engineering, permits and time, and the structure has to be held safely through all of it.

New Age Construction Group stabilizes condominiums, parking structures and commercial buildings for boards, property managers and owners across Miami, Fort Lauderdale, West Palm Beach and all of Miami-Dade County, Broward County and Palm Beach County, 24/7. We coordinate with your engineer of record and the building official from the first hour, and we are the licensed general contractor that performs the structural restoration that follows.

View Our Structural Projects
Shoring towers supporting a distressed concrete beam in a parking structure
Rapid
Response & Mobilization
Cracking and crushing at the base of a concrete column
Call
Before It Gets Worse
Warning Signs

7 Signs a Structure Needs Support Now

Some deterioration can wait for a scheduled fix. These signs cannot. Keep people away and call. Stabilizing the structure comes before diagnosis.

Sudden new cracks, or cracks that widen day to day. Active movement in a load-bearing element means it is losing capacity.

Sagging, deflecting or out-of-level slabs and beams. Deflection under normal load means the element is already overstressed.

Concrete falling from ceilings, soffits or balcony undersides. Spalling, concrete breaking away from corroding rebar, is an immediate hazard once pieces fall. Seeing any of these? Call (786) 786-1006 now

Crushing, bulging or exposed, buckled reinforcement at the base of a column. These fail suddenly; any sign of crushing calls for load relief now.

Doors and windows suddenly binding, or floors out of level. The building is moving and redistributing load.

Storm, vehicle or fire damage to a structural element. Impact and heat compromise structural integrity in ways you cannot see.

An unsafe-structure notice or a Phase Two milestone finding of imminent risk. The building official or your engineer has already decided the element cannot be trusted.

Seeing any of these? Call (786) 786-1006 now
Our Capabilities

Emergency Stabilization Services

Load relief first, then the path to the permanent fix.

Rapid Response Shoring

Post shores (adjustable steel props), towers and needle beams that transfer load off compromised columns, beams and slabs. Mobilized fast, designed to the real loads.

Storm & Impact Damage Response

Emergency support after hurricanes, vehicle impacts and fire, so the structure is safe to assess, occupy and repair.

Unsafe Structure Notice Response

Temporary support and documentation built to give Miami-Dade and Broward building officials what they need to keep a building occupied.

Lateral Bracing & Rakers

Rakers, which are angled supports, and bracing for load-bearing walls, facades and parapets, keeping unstable walls standing until facade restoration corrects the cause.

Milestone Phase Two & Imminent Risk Findings

Immediate support for elements a milestone or 40-year recertification inspection flags as at risk, so the building stays occupied while repairs are scheduled.

Transition to Permanent Repairs

Supports that stay through engineering, permitting and construction, and come out when the permanent structural repair or strengthening takes the load.

What Is Emergency Shoring, and What It Isn't

In plain terms, it is temporary support for a structure that is failing or at risk of structural failure right now. It exists to transfer load, stabilize the structure and prevent further collapse until a permanent fix is in place. The supports bear on sound structure or soil and are monitored for stability until the repair takes over. It is not a repair.

Four other things share the name. Construction re-shoring is the shoring construction crews set under fresh concrete and formwork while it cures; it supports new work, not distressed work. Trench and excavation systems hold back soil so workers can enter an excavation; they protect a hole, not a building. Technical rescue work is what fire departments do after a collapse. Scaffolding gives access and carries no structural load.

When a Structure Needs Support

The triggers fall into three groups. Sudden events: hurricane and storm damage, vehicle impacts in parking garages, fire, settlement or sinkhole activity. Deterioration that has reached a critical stage: chloride driven corrosion that has crushed a column base, a balcony or garage slab that has begun to deflect, concrete falling from ceilings. And official findings: an unsafe-structure notice, a failed inspection, or a Phase Two milestone inspection that identifies an element at imminent risk.

In every case, support the structure first, with people out of harm's way, then diagnose, engineer and permit.

Emergency Shoring Systems We Install

Every emergency is different, so the shoring techniques are chosen for the load, the geometry and the access, then checked by the structural engineer before any load is transferred.

  • Post shores and shoring jacks. Adjustable steel or aluminum props, the vertical supports that carry slab and beam loads down to the floor below. Set on plates, tightened with shims (thin wedges), and often topped with header beams so one row of posts carries a wide area.
  • Towers and braced frames. Stacked frames for heavy loads or tall clear heights, with lateral support built in.
  • Needle beams. Steel beams threaded through a wall or beside a damaged member to pick up load from above so a section can be rebuilt.
  • Rakers and lateral bracing. Angled supports that lean against a wall, facade or parapet and carry lateral load to the ground or an adjacent slab.
  • Dead shores and flying shores. The first carries a floor, roof or beam, including wood floor joists in older buildings, while the wall below is rebuilt. The second spans between two walls on wall plates when there is no room for supports from the ground.
  • Cribbing, mats and stacking. Timber cribbing, plywood panels and load spreading mats put concentrated loads onto sound slab or soil. Over several floors, the supports are stacked so the load travels down to the foundation.

The same shoring techniques that hold a garage slab hold a balcony stack; what changes is the engineering. The shoring process ends the same way every time: bearing, plumb and connections checked before load is transferred.

Temporary Shoring Permits in Miami-Dade and the City of Miami

In Miami-Dade County, temporary shoring is permitted work. The Temporary Shoring permit, issued through the Miami-Dade County Permitting and Inspection Center, runs on an engineering submittal: a permit application with the property owner's notarized signature, an engineering report on the condition of the building, a shoring plan marking every deficiency and every support with heights and design loads, load calculations for the slab or soil the posts bear on, and a letter stating the building is safe to occupy while supported. All of it signed and sealed by a Florida Professional Engineer. In threshold buildings (under Florida law, generally any building taller than three stories or 50 feet, which covers most condominium towers) the county also requires a special inspector for the installation. A "Final" (001) inspection with the engineer's letter closes the permit, and the permanent work runs under its own repair permit. Where an element is actively failing, we coordinate emergency timing with the building official while the submittal is prepared.

In the City of Miami, after a declared hurricane or tropical storm, temporary bracing installed to prevent further structural damage is exempt from a permit under the City of Miami Building Department's Post-Storm Permitting Plan. Bracing that stays, temporary structural support and unsafe structure corrections run under Emergency Stabilization Permits, and load bearing element repairs run under a separate Structural Permit. The department expedites both, with the goal of issuing permits within a few business days when the submittal is complete, and inspections that may be scheduled within 24 to 48 hours of request.

New Age prepares the field information, coordinates the submittal with your engineer of record and schedules the inspections.

After a Hurricane: Securing and Documenting the Building

The first hour after a storm or other disaster is about hazards: live electrical, gas, falling debris and the parts of the structure that moved. We cordon the area, install temporary bracing and start documenting. Dated photographs and a written condition record, before and after the supports go in, are what your insurer, your board and the building official will ask for, and what your engineer uses to scope the permanent repairs.

If the building sits in a FEMA Special Flood Hazard Area, the City of Miami will not issue a permit until a Substantial Damage Determination is finalized; a structure is substantially damaged when repairs would cost 50 percent or more of its pre storm market value. Permits that affect life safety and the structure are reviewed first, so a complete submittal moves fastest.

Unsafe Structure Notices, Milestone Findings and Compliance

Miami-Dade, Broward and their municipalities can issue unsafe-structure notices that can require immediate support and can lead to a building being ordered vacated. Florida's milestone inspection law adds a second path: when a Phase Two report (the detailed inspection ordered after the Phase One visual inspection finds substantial deterioration) identifies substantial structural deterioration, the association must commence repairs within 365 days of receiving the report and show the local building department that the work is scheduled or under way. A 40-year recertification report can surface the same findings; a structural integrity reserve study flags the components that need attention next.

New Age responds with engineer verified supports, documents the installation for the building official and your board, and carries the structure through permitting and the permanent structural repair, built to close the notice, not escalate it.

Don't Wait

A Distressed Structure Doesn't Wait

Structural failures happen suddenly. Here is what load relief prevents.

Collapse & Life Safety Risk

An element past its capacity has no margin left. Load relief removes the risk while the permanent fix is engineered.

Forced Evacuation & Closure

Unaddressed unsafe-structure findings lead to buildings ordered vacated and garages closed. Early support is what keeps most buildings occupied and most garages open.

Contained vs Cascading Damage

A supported element is one job. An element that fails takes adjacent structure with it. Early support is almost always the cheapest line item in a structural emergency.

Pricing Transparency

What Determines the Cost of Emergency Support in South Florida

Four factors drive the cost.

Extent & Loads Involved

A single garage beam prices very differently than a multi story balcony stack.

Duration

Shoring rental runs for the life of the repair, usually weeks to months; the permit itself states the expected duration.

Access & Stacking

Elevated elements, occupied units and stacked supports over several floors are the largest variables.

Engineering & Documentation

Load verification with the engineer of record, the permit submittal and documentation for the building official are itemized.

Pricing is transparent as we go, and every proposal for the permanent work is free and itemized. No hidden mobilization fees.

Call for immediate response

If a structure is showing distress, don't wait. Call now.

24/7 emergency response across Miami-Dade, Broward and Palm Beach County.

How It Works

From Your Call to a Stabilized Structure

Shoring operations follow a clear sequence.

01

Emergency Call & Site Response

Call, describe what you are seeing, and we mobilize. On site we secure the area, control access and assess the element.

02

Structural Assessment & Design

We verify field conditions, loads and the bearing path with your engineer of record, who seals the design, documented for the building official where a notice is involved.

03

Permit Submittal & Special Inspection

We assemble the field information for the Temporary Shoring permit, coordinate the signed and sealed submittal, and schedule the special inspector for threshold buildings.

04

OSHA Certified Installation

Sequenced with the building official: under the City of Miami's declared storm exemption bracing goes in first; otherwise it follows the permit, with emergency timing coordinated case by case. Crews install on sound bearing with signage and access control so residents, workers and vehicles stay clear, and every bearing point is checked for safety before the supports take load.

05

Monitoring, Inspection & Transition

The supports are monitored for stability and inspected through permitting, then removed once the permanent structural repair or strengthening carries the load.

Why New Age

The Emergency Response Team South Florida Trusts

OSHA Certified Workforce

Every superintendent holds a 30 hour OSHA certification and every laborer completes 10 hour OSHA safety training.

State Licensed & Fully Insured

Licensed General Contractor CGC#1531273. General Liability and Workers' Compensation coverage on every project.

Deep South Florida Expertise

We work inside the Florida Building Code's High Velocity Hurricane Zone provisions and the Miami-Dade and Broward recertification programs every week.

One Contractor, Start to Finish

The crew that supports the structure is the licensed general contractor that performs the concrete restoration and structural work that follows. No handoff, no second mobilization.

Our Work

Projects We're Proud Of

Miami Garage Emergency Slab Support & Restoration
Emergency Shoring

Miami Garage Emergency Slab Support & Restoration

Miami-Dade County
View Project
Hollywood Post Storm Balcony Stack Support
Emergency Shoring

Hollywood Post Storm Balcony Stack Support

Broward County
View Project
Boca Raton Column Support Through Recertification Repair
Emergency Shoring

Boca Raton Column Support Through Recertification Repair

Palm Beach County
View Project
Florida Compliance

Stabilize First. Then Close the Notice.

We have worked every one of these paths: unsafe-structure notices in Miami-Dade and Broward, Phase Two milestone findings on a 365-day clock, and county permits that run on a sealed engineering submittal.

Call About an Unsafe-Structure Notice
365 Daysto Commence Repairs
24/7Response
3Counties
Client Testimonials

What Property Owners & Managers Are Saying

Google Reviews4.9
★★★★★
★★★★★

"New Age Construction completely restored the structural damage on our building. Professional team, excellent communication, and the results exceeded our expectations. Highly recommend."

MR
Maria R.
Verified Google Review
★★★★★

"After experiencing water damage, we needed immediate waterproofing solutions. New Age responded quickly and did an outstanding job. Our building has been protected ever since."

DC
David C.
Verified Google Review
★★★★★

"Great experience working with New Age Construction. They handled our structural repairs with expertise and care."

LK
Lisa K.
Verified Google Review
4.9
★★★★★
Based on 50+ Google Reviews
Coverage Area

Emergency Response Across South Florida

We respond to structural emergencies at condominiums, parking structures, HOAs and commercial buildings throughout Miami-Dade, Broward and Palm Beach County, 24/7.

Miami-Dade County

In Miami, from Brickell and Downtown towers to Coral Gables condominiums and Doral garages, and across Miami Beach, Aventura, Hialeah and Homestead, with direct experience responding to unsafe-structure notices and preparing county permit submittals.

Broward County

In Fort Lauderdale and Hollywood, and in Pembroke Pines, Miramar and Sunrise, including post hurricane response along the coastline. Fort Lauderdale high rises and garages are a regular call.

Palm Beach County

From West Palm Beach to Boca Raton, Delray Beach and Boynton Beach, for condominium associations and commercial owners, including imminent risk milestone findings.

Is a Structure Showing Distress Right Now?

Keep people clear and call.

Call (786) 786-1006Request an Assessment
FAQ

Frequently Asked Questions About Emergency Shoring

Get Help Now

Structural Emergency? Call First, Then Send the Details

For an active emergency, call (786) 786-1006. We mobilize while you are on the phone. Use the form for non urgent needs or to send photos after your call; a senior project manager follows up within one business day.

24/7 emergency response
Engineer-coordinated stabilization
Licensed GC on every response
Emergency line — 24/7
(786) 786-1006

Tell Us What You're Seeing

For active emergencies, call (786) 786-1006. By submitting this form you agree to be contacted by our team. We never share your information.

Your Request Has Been Submitted!

Thank you for reaching out to New Age Construction Group. A senior project manager will review your details and contact you within one business day.

Need immediate assistance? Call (786) 786-1006